Gi500 Standard Control Features

1 Full Load Control Once the elevators is loaded to 80% of rated capacity, all landing calls will be by-passed while all car calls will be attended.
2 Overload Control If a car is overloaded , new starting will be prevented, and doors will remain open with an audio-visual indication in car signaling overload condition.
3 Auto Fan Shutoff The fan is switched off automatically at a preset time after attending the last car call.
4 Fireman's Control This facility is to be exclusively used by fire fighting personnel for rescuing trapped persons in the building.
5 Automatic Return The Car returns to a designated floor after attending all calls. This is preferential treatment to a designated floor.
6 Phase Failure & Reversal Protection This protects the controller and motor from burn out. The elevators will be stopped if phase failure is detected.
7 Main Parking Floor An available car will be parked at the main floor with doors open/closed.
8 Mechanical Door Safety If door are obstructed while closing they will retract on applying gentle pressure. This acts as a backup to infrared safety.
9 By-pass If any car button or landing button is stuck or kept pressed deliberately, the elevators will bypass that call and continue to attend other calls.
10 Continuity of Service A car experiencing trouble is automatically removed from group operation to protect the overall group performance. Calls assigned to this car will be distributed to others in the group
11 'Elevators Here' Flash Landing push button light flashes to indicate car arrival or if the car is parked. This feature is provided in elevators with Simplex Controls
12 Programmability The controller is programmable with the help of a dedicated console. Several parameters (e.g. Single Control, Group Control, Anti Nuisance, etc.) can be quickly reprogrammed
13 Motherboard Temperature Protection Upon reaching the preset temperature limit, the elevators stops automatically, and will start functioning when the temperature normalises.
14 Short Circuit Protection A safety circuit on the motherboard prevents damage to the main procesor. Simplified cabling by using intelligent I/O devices.
15 Self Diagnostic Problems are diagnosed automatically by the controller. Faults are recorded by the controller for analysis.
16 Anti Nuisance This feature helps to avoid unnecessary movement of the elevators caused by mischievously erroneously registered car calls.
17 Double Door Operation Fully programmable double door operation is supported.
18 Car Arrival Chime An electronic chime sounds to inform waiting passengers of the car's arrival. This applies to elevators in Group Control.
19 Advance Door Opening This allows the doors to begin opening before the car stops at the destination floor, and improves Round Trip Time.
20 Independent Service An elevator can be isolated from the group and operated from the car without interruption.
21 Press & Speak Intercom The car operating panel is provided with push button operated microphone and speaker. Communication is possible between passengers and reception or security.
22 Light Curtain A highly sensitive full-length infra-red door safety screen is provided on the car doors.